1130 East Center Street

Spanish Fork, UT, 84660

January 17th, 2023

INSPECTED BY

Mark Larsen

PREPARED FOR

Angela Larsen

Approximate Humidity

85%

Approximate Temperature

33° F

Estimated Square Feet

1800

Furnished

Yes

Number of Bathrooms

Two

Number of Bedrooms

Two

Number of Stories

One

Present at inspection

Buyer

Structure Orientation

East

Weather Conditions

Possible drizzle in the afternoon.

Year Built

1975

General Information

This report is the exclusive property of our home inspection service and the client whose name appears herewith, and its use by any unauthorized persons is strictly prohibited.

The observations and opinions expressed within this report are those of our home inspection service and supersede any alleged verbal comments. This report overrides, supersedes and negates any previous report that may have been submitted by us for this property and should be read in its entirety. Any reports previously submitted by us for this property should be destroyed and should not be relied upon or considered accurate or complete.

We inspect all of the systems, components, and conditions described in accordance with the standards of the International Association of Certified Home Inspectors (iNACHI), and those that we do not inspect are clearly disclaimed in the contract and/or in the aforementioned standards. However, some components that are inspected and found to be functional may not necessarily appear in the report, simply because we do not wish to waste our client's time by having them read an unnecessarily lengthy report about components that do not need to be serviced.

California Business & Professions Code, Section 7195 provides the following definition for a home inspection;

A home inspection is a noninvasive, physical examination, performed for a fee in connection with a transfer, as defined in subdivision (e), of real property, of the mechanical, electrical, or plumbing systems or the structural and essential components of a residential dwelling of one to four units designed to identify material defects in those systems, structures and components. A home inspection also includes any consultation regarding the property that is represented to be a home inspection or any confusingly similar term.

This same section of the CA B&P Code defines a "material defect" as a condition that significantly affects the value, desirability, habitability, or safety of the dwelling. Style or aesthetics shall not be considered in determining whether a system, structure, or component is defective.

In short, a home inspection is intended to assist in evaluation of the overall condition of the dwelling. The report is not intended to be a "check list" of items that need repair or general maintenance, it is designed to identify material defects or deficiencies that would have an adverse impact on the value of the real-property, or that involve an unreasonable risk to people on the property. This home inspection report will likely reveal many minor defects discovered during our examination of the property, but it will not reveal every condition that exists or ever could exist, and is intended to identify only those material defects that were observed on the day of the inspection.

In accordance with the terms of the contract, the investigation and service recommendations that we make in this report should be completed during your inspection contingency period by qualified, licensed specialists, who may well identify additional defects or recommend some upgrades that could affect your evaluation of the property.

The failure to follow our recommendations constitutes a violation of our agreement and contract, which would hold us harmless for any subsequently alleged defects or deficiencies and by relying on this inspection report you have agreed to be bound by the terms, conditions and limitations as set forth in the CONTRACT AGREEMENT, which was presented to you at the time of the inspection or in an electronic attachment included with your completed report. If you do not have a copy of the CONTRACT AGREEMENT please contact us and a copy will be provided to you either electronically or by fax. If you do not agree to be bound by this CONTRACT AGREEMENT in its entirety, you must contact us immediately upon receipt of this completed report. In addition, all electronic and paper copies of the inspection report must be deleted and destroyed, and may not be used in whole or in part for consideration in a real estate transaction.

Your completed report may contain photographs of various conditions noted during the inspection.

PHOTOGRAPHS PROVIDED IN THIS REPORT ARE INTENDED TO HELP INTERESTED PARTIES UNDERSTAND THE CONTEXT OF THIS REPORT, BUT MAY NOT REPRESENT THE SUM TOTAL OF ALL CONDITIONS.

Scope of Work

You have contracted with our home inspection service to perform a generalist inspection in accordance with the standards of practice established by the National Association of Certified Home Inspectors, a copy of which is available upon request. Generalist inspections are essentially visual, and distinct from those of specialists, inasmuch as they do not include the use of specialized instruments, the dismantling of equipment, or the sampling of air and inert materials. Consequently, a generalist inspection and the subsequent report will not be as comprehensive, nor as technically exhaustive, as that generated by specialists, and it is not intended to be. The purpose of a generalist inspection is to identify significant defects or adverse conditions that would warrant a specialist evaluation. Therefore, you should be aware of the limitations of this type of inspection, which are clearly indicated in the standards. However, the inspection is not intended to document the type of cosmetic deficiencies that would be apparent to the average person, and certainly not intended to identify insignificant deficiencies.

Most homes built after 1978, are generally assumed to be free of asbestos and many other common environmental contaminants. However, as a courtesy to our clients, we are including some well documented, and therefore public, information about several environmental contaminants that could be of concern to you and your family, all of which we do not have the expertise or the authority to evaluate, such as asbestos, radon, methane, formaldehyde, termites and other wood-destroying organisms, pests and rodents, molds, microbes, bacterial organisms, and electromagnetic radiation, to name some of the more commonplace ones. Nevertheless, we will attempt to alert you to any suspicious substances that would warrant evaluation by a specialist. However, health and safety, and environmental hygiene are deeply personal responsibilities, and you should make sure that you are familiar with any contaminant that could affect your home environment. You can learn more about contaminants that can affect you home from a booklet published by The environmental Protection Agency, which you can read online at www.epa.gov/iaq/pubs/insidest.htm.

Mold is one such contaminant, and is present to some degree in nearly every residence. It is a microorganism that has tiny seeds, or spores, that are spread on the air, land, and feed on organic matter. It has been in existence throughout human history, and actually contributes to the life process. It takes many different forms, many of them benign, like mildew. Some characterized as allergens are relatively benign but can provoke allergic reactions among sensitive people, and others characterized as pathogens can have adverse health effects on large segments of the population, such as the very young, the elderly, and people with suppressed immune systems. However, there are less common molds that are called toxigens that represent a serious health threat. All molds flourish in the presence of moisture, and we make a concerted effort to look for any evidence of it wherever there could be a water source, including that from condensation. Interestingly, the molds that commonly appear on ceramic tiles in bathrooms do not usually constitute a health threat, but they should be removed. However, some visibly similar molds that form on cellulose materials, such as on drywall, plaster, and wood, are potentially toxigenic. If mold is to be found anywhere within a home, it will likely be in the area of tubs, showers, toilets, sinks, water heaters, evaporator coils, inside attics with unvented bathroom exhaust fans, and return-air compartments that draw outside air, all of which are areas that we inspect very conscientiously. Nevertheless, mold can appear as though spontaneously at any time, so you should be prepared to monitor your home, and particularly those areas that we identified. Naturally, it is equally important to maintain clean air-supply ducts and to change filters as soon as they become soiled, because contaminated ducts are a common breeding ground for dust mites, rust, and other contaminants. Regardless, although some mold-like substances may be visually identified, the specific identification of molds can only be determined by specialists and laboratory analysis, and is absolutely beyond the scope of our inspection. Nonetheless, as a prudent investment in environmental hygiene, we categorically recommend that you have your home tested for the presence of any such contaminants, and particularly if you or any member of your family suffers from allergies or asthma. Also, you can learn more about mold from an Environmental Protection Agency document entitled "A Brief Guide to Mold, Moisture and Your Home," by visiting their web site at: http://www.epa.gov/iaq/molds/moldguide.html/, from which it can be downloaded.

Asbestos is a notorious contaminant that could be present in any home built before 1978. It is a naturally occurring mineral fiber that was first used by the Greek and Romans in the first century, and it has been widely used throughout the modern world in a variety of thermal insulators, including those in the form of paper wraps, bats, blocks, and blankets. However, it can also be found in a wide variety of other products too numerous to mention, including duct insulation and acoustical materials, plasters, siding, floor tiles, heat vents, and roofing products. Although perhaps recognized as being present in some documented forms, asbestos can only be specifically identified by laboratory analysis. The most common asbestos fiber that exists in residential products is chrysotile, which belongs to the serpentine or white-asbestos group, and was used in the clutches and brake shoes of automobiles for many years. However, a single asbestos fiber is said to be able to cause cancer, and is therefore a potential health threat and a litigious issue. Significantly, asbestos fibers are only dangerous when they are released into the air and inhaled, and for this reason authorities such as the Environmental Protection Agency [EPA] and the Consumer Product Safety Commission [CPSC] distinguish between asbestos that is in good condition, or non-friable, and that which is in poor condition, or friable, which means that its fibers could be easily crumbled and become airborne. However, we are not specialists and, regardless of the condition of any real or suspected asbestos-containing material [ACM], we would not endorse it and recommend having it evaluated by a specialist.

Radon is a gas that results from the natural decay of radioactive materials within the soil, and is purported to be the second leading cause of lung cancer in the United States. The gas is able to enter homes through the voids around pipes in concrete floors or through the floorboards of poorly ventilated crawlspaces, and particularly when the ground is wet and the gas cannot easily escape through the soil and dispersed into the atmosphere. However, it cannot be detected by the senses, and its existence can only be determined by sophisticated instruments and laboratory analysis, which is completely beyond the scope of our service. However, you can learn more about radon and other environmental contaminants and their affects on health, by contacting the EPA or a similar state agency, and it would be prudent for you to enquire about any high radon readings that might be prevalent in the general area surrounding your home.

Lead poses an equally serious health threat. In the 1920's, it was commonly found in many plumbing systems. In fact, the word "plumbing" is derived from the Latin word "plumbum," which means lead. When in use as a component of a waste system, it does not constitute a viable health threat, but as a component of potable water pipes it would certainly be a health-hazard. Although rarely found in use, lead could be present in any home build as recently as the nineteen seventies. For instance, lead was an active ingredient in many household paints, which can be released in the process of sanding, and even be ingested by small children and animals chewing on painted surfaces. Fortunately, the lead in painted surfaces can be detected by industrial hygienists using sophisticated instruments, but testing for it is not cheap. There are other environmental contaminants, some of which we have already mentioned, and others that may be relatively benign. However, we are not environmental hygienists, and as we stated earlier we disclaim any responsibility for testing or establishing the presence of any environmental contaminant, and recommend that you schedule whatever specialist inspections that may deem prudent during your inspection contingency period.

1 · Exterior

Site & Other Observations

1.1 · Renovations & Additions

Additions have been made to this property. Therefore, you should request documentation that should include a certificate of occupancy from the building department, permits and any warranties or guarantees that might be applicable, because we do not approve of, or tacitly endorse, any work that was completed without permits, and latent defects could exist.
Further Investigation Advised

1.2 · Renovations & Additions

The property has been renovated or remodeled. Therefore, you should request documentation that should include a certificate of occupancy from the building department, building permits and any warranties or guarantees that might be applicable, because we do not approve or tacitly endorse any work done without permits, and latent defects will likely exist.
Further Investigation Advised

1.3 · Landscaping Observations

The roots of mature trees could have an adverse effect on either the water main or the sewer pipe, and it would be prudent to have the trees removed. In any event, you should consult an arborist who could predict future growth potential.
Other

Grading & Drainage

1.4 · General Comments

Water is destructive, and if it's not given a way around a residence it will likely find a way in. For this reason the ideal residence is surrounded by surfaces that slope away from it for a minimum of six feet, and it has interior floors that are several inches higher than the exterior grade. It has roof gutters that discharge into area drains that convey water to a street or other hard surface. Unfortunately, many older residences don't meet this ideal, and people often fail to realize why positive drainage is essential until a problem occurs. Water not only flows on surfaces but beneath them as well and can penetrate walls and floors by capillary action or hydrostatic pressure, for which reason, capillary breaks and French drains are typically installed on modern sites to protect residences against moisture intrusion. A capillary break consists of layers of sand and gravel and a vapor barrier underneath a slab, and a French drain consists of five inch diameter tubes with holes facing the direction of the flow. They're typically enclosed in a sleeve or sock and encased in a bed of gravel in a trench that parallels a footing below the level of a floor, where they not only receive subterranean water that takes the path of least resistance, but can also receive water from roof gutters and area drains. However, area drains are only as good as their type and size. The least efficient are usually round and two or three inches in diameter, which are not only difficult to clean by hand but are easily obstructed by debris. The most efficient are five or six inches wide or larger and are similar to catch-basins that discharge close to the middle of the drain and allow any sediment or debris that's washed in to drop to the bottom where it can be easily removed. All area drains can be displaced by soil movement or blocked by roots and sedimentary material, and we don't flush-test them because it could literally take hours of time and hundreds of gallons of water, or entail the use of equipment or high-pressure hoses, for which reason we cannot guaranty that a drainage system will function as it's intended. We cannot guarantee the condition of any subterranean drainage system, and if a property does not meet this ideal, or if any portion of the interior floor is below the exterior grade, we cannot endorse it and recommend that you consult with a grading and drainage contractor, even though there may not be any evidence of moisture intrusion.
Informational

1.5 · Moisture & Related Issues

Moisture intrusion is a perennial problem, with which you should be aware. It involves a host of interrelated factors, and can be unpredictable, intermittent, or constant. When moisture intrusion is not self evident, it can be inferred by musty odors, peeling paint or plaster, efflorescence, or salt crystal formations, rust on metal components, and wood rot. However, condensation and humidity can produce similar conditions if the temperature in an area is not maintained above the dew point. Regardless, if the interior floors of a residence are at the same elevation or lower than the exterior grade we cannot rule out the potential for moisture intrusion and would not endorse any such areas. Nevertheless, if such conditions do exist, or if you or any member of your family suffers from allergies or asthma, you should schedule a specialist inspection.
Informational

1.6 · Interior-Exterior Elevations

The crawl space could be subject to moisture intrusion and the presence of salt crystal formations on the basement walls confirms that moisture does reach this area. Therefore, you should ask the sellers about their experience with this, keep any storage items isolated from the walls and floors, monitor the crawl space during heavy rains, and have a portable sump-pump ready for emergencies.
Informational

1.7 · Drainage Mode

Drainage on this property is solely dependant on soil-percolation and hard surfaces. Such conditions are not ideal, and water may pond at various points during prolonged rains. Therefore, you may wish to have a specialist evaluate, but we did not see any evidence of moisture contaminating the living space.
Other

1.8 · Flat & Level Pad

The residence is situated on a flat level pad, which would typically not need a geological evaluation. However, we do not have the authority of a geologist and you may wish to have a site evaluation.
Informational

House Wall Finish

1.9 · General Comments

The house walls are generally wrapped with a waterproof or water-resistant barrier prior to installation of the finished covering. This barrier is an essential component, and proper installation is critical to water proofing the exterior walls. However, this barrier is concealed and not visible during the course of a generalists inspection. We do not perform water tests or leak tests, therefore, we cannot guarantee the integrity of this barrier and specifically disclaim any responsibility for defects that may exist or that may develop over time, and indications of damage or defects in the waterproof barrier may only become evident during heavy, prolonged or wind-driven rainfall. For a guarantee against leaks or defects in the waterproof barrier of the exterior walls, you would need to hire a qualified contractor to perform a water test. In addition, any system or component that has been subsequently attached to the structure, such as patio covers, decks, awnings, satellite dishes, etcetera, will have unavoidably pierced the waterproof barrier at the attachment points and will remain a potential point of moisture intrusion.
Informational

1.10 · House Wall Finish Type

The house walls consist of bricks veneer.
Informational

Exterior Components

1.11 · Driveways

The driveway is in acceptable condition.
Informational

1.12 · Walkways

There is an offset on a walkway that could prove to be a trip-hazard.
Other

1.13 · Window Advisory

In accordance with industry standards, we do not test every window in the house, and particularly if the house is furnished. There are many styles of windows but only two basic types, single and dual-glazed. Dual-glazed windows are superior, because they provide a thermal barrier, as well as an acoustical barrier. However, the hermetic seals on these windows can fail at any time, and cause condensation to form between the panes. Unfortunately, this is not always apparent, which is why we disclaim any evaluation of hermetic seals. In addition, the proper installation of windows and the flashings around windows is critical to water proofing the exterior walls. Missing, damaged or improperly installed flashings, and improperly installed windows are the most common cause of moisture intrusion to walls and baseboards beneath windows. Because the flashings are concealed by the exterior wall covering, we cannot endorse them and specifically disclaim any evaluation of these flashings, and leaks may become evident only during heavy, prolonged or wind-driven rainfall. Nevertheless, in accordance with industry standards, we test a representative number of unobstructed windows, and ensure that at least one window in every bedroom is operable and facilitates an emergency exit.
Informational

1.14 · Windows

The windows appear to be the same age as the residence and will not necessarily function smoothly. Window rollers and track systems for horizontally operated windows may not seal or operate effectively, and the thermal insulating factor of these windows is significantly inferior to newer, dual-paned windows. We do not necessarily consider aged systems or components to be materially defective, however, you should consider having the windows replaced at some point, if for no reason other than to increase the energy efficiency of the home.
Informational

1.15 · Screens

The window screens are functional.
Informational

1.16 · Exterior Doors

The exterior doors need typical maintenance-type service.
Other

1.17 · Fascia & Trim

The fascia and trim need maintenance type service, and particularly where they are exposed to direct sunlight. Regular maintenance will help prevent moisture intrusion and infestation from wood-destroying insects
Needing Service

1.18 · Fences & Gates

The fences and gates are workable and would not need service at this time.
Functional

1.19 · Lights

The lights outside the doors of the residence are functional. However, we do not inspect or evaluate decorative lights, low voltage lighting, yard lights or any other lighting systems that are not directly attached to the residence structure.
Functional

1.20 · Outlets

The exterior receptacles of the residence do not include ground-fault protection, which is required and should be established by a qualified electrician.
Needing Service

1.21 · Exterior Electrical Observations

There are unprofessional circuit installations at various points on the property, which should be serviced or removed by a qualified electrician for reasons of safety and compliance.
Needing Service

1.22 · Steps & Handrails & Guardrails

The steps are in acceptable condition.
Functional

1.23 · Fire Pit

There is a fire pit on the property that we did not evaluate, and which you may wish to have demonstrated by the sellers. However, you should be aware that components employing natural gas are inherently dangerous.
Informational

1.24 · Portable Spa

The portable spa is not inspected as part of our service.
Informational

2 · Structural

Various Hard Surfaces

2.1 · Common Observations

The visible portions of the hard surfaces, such as the house walls, yard walls, walkways, and decks have no significant cracks that would tend to suggest structural movement.
Other

Structural Elements

2.2 · Identification of Floor Structure

The floor structure consists of posts piers girders and joists sheathed with plywood or diagonal boards.
Informational

2.3 · Identification of Roof Structure

The roof structure is framed with a combination of an engineered truss system, and a conventional system including rafters, purl-ins, collar-ties, etc.
Informational

2.4 · Identification of Ceiling Structure

The ceiling structure consists of a combination of standard joists, and engineered joists that are part of a prefabricated truss system.
Informational

2.5 · Identification of Wall Structure

The walls are conventionally framed with wooden studs.
Informational

Slab Foundation

2.6 · Common Observations

.
Other

Raised Foundation

2.7 · General Comments

This residence has a raised foundation. Such foundations permit access, and provide a convenient area for the distribution of water pipes, drain pipes, vent pipes, electrical conduits, and ducts. Although raised foundations are far from uniform, most include concrete footings and walls that extend above the ground with anchor bolts that hold the house onto the foundation, but the size and spacing of the bolts vary. In the absence of major defects, most structural engineers agree that the one critical issue with raised foundations is that they should be bolted. Our inspection of these foundations conforms to industry standards, which is that of a generalist and not a specialist, and we do not use any specialized instruments to establish that the structure is level. We attempt to enter all accessible areas, to confirm that foundations are bolted and to look for any evidence of structural deformation or damage, but we may not comment on minor deficiencies, such as on commonplace settling cracks in the stem walls and slight deviations from plumb and level in the intermediate floor framing, which would have little structural significance. There is no absolute standard for evaluating cracks, but those that are less than 1/4" and which do not exhibit any vertical or horizontal displacement are generally not regarded as being structurally relevant. Nevertheless, all others should be evaluated by a specialist. In the absence of any major defects, we may not recommend that you consult with a foundation contractor, a structural engineer, or a geologist, but this should not deter you from seeking the opinion of any such expert. We attempt to access every crawlspace to determine if any deficiencies exist in the components within the crawlspace. However, we will not enter any crawlspace or area of a crawlspace that we consider dangerous, or that which would require us to remove our personal-protection equipment (PPE) in order to gain access. Many older crawlspaces have clearances that would be considered inadequate by today's standards, but are generally considered acceptable and do not necessarily require service to increase clearances and meet newer standards. In such cases, we will indicate in the report whether we were able to access the entire crawlspace and what limitations may have prevented full access.
Informational

2.8 · Method of Evaluation

We evaluated the raised foundation by accessing and evaluating the components within the crawlspace.
Informational

2.9 · Crawlspace Observations

The crawlspace is accessible and in acceptable condition.
Informational

2.10 · Intermediate Floor Framing

The intermediate floor framing is in acceptable condition. There may be some deviations from plumb, level, etc, but none that would have any serious structural significance.
Informational

2.11 · Floor Insulation

There is no floor insulation, which would not have been required when this residence was constructed.
Informational

3 · Roof

Composition Shingle Roof

3.1 · Composition Shingle General Comments

There are a wide variety of composition shingle roofs, which are comprised of asphalt or fiberglass materials impregnated with mineral granules that are designed to deflect the deteriorating ultra-violet rays of the sun. The most common of these roofs are warranted by manufacturers to last from twenty to twenty-five years, and are typically guaranteed against leaks by the installer for three to five years. The actual life of the roof will vary, depending on a number of interrelated factors besides the quality of the material and the method of installation. The first indication of significant wear is apparent when the granules begin to separate and leave pockmarks or dark spots. This is referred to as primary decomposition, which means that the roof is in decline, and therefore susceptible to leakage. This typically begins with the hip and ridge shingles and to the field shingles on the south facing side. This does not mean that the roof needs to be replaced, but that it should be monitored more regularly and serviced when necessary. Regular maintenance will certainly extend the life of any roof, and will usually avert most leaks that only become evident after they have caused other damage.
Informational

3.2 · Estimated Age

The roof appears to be 15 to 20 years old, but this is only an estimate.
Informational

3.3 · Shingle Condition

The roof covering is in the primary stages of decomposition, which means that the roof is in decline and susceptible to leaks. It will need to be maintained and closely monitored, because it is reaching the end of its serviceable life. In addition, we strongly suggest that you obtain a second opinion from a qualified roofing contractor during your inspection contingency period.
Recommend Upgrade

3.4 · Layered Material

The roofing material has been layered, which is not recommended. Layered material adds weight to the structure and will decrease the life expectancy of the newer roof covering material.
Informational

3.5 · Gutters & Drainage

The gutters need to be serviced and re-leveled by a licensed contractor.
Needing Service

4 · Plumbing

Potable Water Supply Pipes

4.1 · Public Water Supply

The potable water is supplied to the residence by a public utility company.
Informational

4.2 · Water Meter Location

The water meter is located in the front of the residence.
Informational

4.3 · Pressure Regulators

A functional pressure regulator is in place on the plumbing system. A water pressure regulator is a valve that automatically cuts off, or reduces the flow of water at a certain pressure. Regulators are used to allow high-pressure water supply lines or tanks to be reduced to safe and/or usable pressures for residential applications.
Informational

4.4 · Copper Water Pipes

The potable water pipes are in acceptable condition.
Informational

4.5 · PEX or Cross-Linked Polyethylene Water Pipes

In some areas this residence is served by Cross-Linked Polyethylene (PEX) potable water pipes that are in satisfactory condition.
Informational

General Gas Components

4.6 · Gas Main Shut-Off Location

The gas main shut-off is located in the garage side yard. You should be aware that gas leaks are not uncommon, particularly underground ones, and that they can be difficult to detect without the use of sophisticated instruments, which is beyond the scope of a typical home inspection. Therefore, we recommend that you request a recent gas bill from the sellers, so that you can establish a norm and thereby be alerted to any potential leak.
Informational

4.7 · Gas Main Observations

There is no wrench at the gas shut-off valve to facilitate an emergency shut-off, and we recommend that you buy one and leave it in-place near the valve.
Recommended Safety Upgrade

4.8 · Gas Seismic Shut-Off Valve

The gas main is not equipped with a seismic shut-off valve. A natural gas seismic shut-off valve automatically shuts off your gas service when an earthquake of a sufficient magnitude occurs at your home's location. Although they are not mandated by this jurisdiction, many insurance companies will require that a seismic shut-off valve be installed at the gas main. Therefore, you should check with your insurance provider.
Further Investigation Advised

4.9 · Gas Supply Pipes

The visible portions of the gas pipes appear to be in acceptable condition.
Informational

Waste & Drainage Systems

4.10 · Type of Material

The visible portions of the drainpipes are acrylonitrile butadiene styrene type, or ABS.
Informational

4.11 · Drain Waste & Vent Pipes

The main drainpipe runs a considerable distance from the residence to the street. Therefore it would be prudent to have it video-scanned.
Other

Gas Water Heaters

4.12 · Age Capacity & Location

Hot water is provided by a 5 year old, 50 gallon heater that is located in a garage closet.
Condition to be Monitored and/or Maitained

4.13 · Common Observations

The water heater is functional.
Functional

4.14 · Water Shut-Off Valve & Connectors

There is no water shut-off valve, which is required and should be installed.
Needing Service

4.15 · Gas Shut-Off Valve & Connector

The gas control valve and its connector at the water heater are functional.
Informational

4.16 · Vent Pipe & Cap

The vent pipe is functional.
Informational

4.17 · Over-Temperature and Over-Pressure Safety System

All storage-type (tank-type) water heaters are required to include an over-temperature and over-pressure safety system. Generally, this system will include a standard temperature & pressure relief (TPR) valve and discharge pipe. The purpose of the valve is to relieve excessive temperature or pressure build up inside the tank if it approaches the limits of the tank's safe design range. The discharge pipe is designed to route the discharge of water and steam to a safe location. The valve should be located near the top of the tank, and is usually threaded directly into the tank top itself. To test the valve, lift up on the handle slightly and hot water should discharge out of the overflow pipe.
Informational

4.18 · Relief Valve & Discharge Pipe

The water heater is equipped with a mandated pressure-temperature relief valve.
Informational

4.19 · Drain Valve

The drain valve is in place and presumed to be functional.
Informational

4.20 · Drip Pan & Overflow Pipe

The water heater is equipped with a drip pan and a drain pipe, which is designed to prevent water damage from a leak. Nevertheless, the water heater should be periodically monitored for any signs of a leak.
Informational

4.21 · Combustion Air Vents

There are no combustion-air vents in the water heater closet. These are essential to support complete combustion, and without them carbon monoxide could be produced and pose a threat to the occupants.
Needing Service

4.22 · Seismic Straps

The water heater is seismically secured in accordance with state and local standards.
Informational

4.23 · Expansion Tank

The expansion tank at the water heater is supported by the flexible appliance connectors. This may damage the supply pipes and result in leakage, and the tank should be properly supported by a qualified contractor.
Needing Service

5 · Electrical Service Equipment

Electrical Equipment & Service Panel

5.1 · Service Entrance

The service entrance, mast weather head, and cleat are in acceptable condition.
Informational

5.2 · Service Panel Size & Location

The residence is served by a 150 amp, 120/240 volt panel located in the wash room.
Informational

5.3 · Service Panel Observations

The panel and its components have no visible deficiencies.
Informational

5.4 · Wiring Type

The conductors are predominantly copper throughout the residence
Informational

5.5 · Circuit Breakers

There are no visible deficiencies with the circuit breakers.
Informational

5.6 · Service Equipment Grounding & Bonding

The panel is grounded to a driven rod.
Informational

6 · Heat/AC

HVAC Package Systems

6.1 · Age & Location

The residence is served by a new package system that is located in the washroom.
Informational

6.2 · Furnace

The furnace is functional.
Informational

6.3 · Gas Valve & Connector

The gas valve and connector are in acceptable condition.
Informational

6.4 · Thermostats

The thermostat is functional
Functional

6.5 · Metal Ducting

The ducts have no visible deficiencies. They are a rigid metal type that are insulated with fiberglass.
Informational

HVAC Heat Pump Systems

6.6 · Heat Pump & Air-Handler

The heat pump responded to a request for cooling.
Informational

6.7 · Return-Air Compartment

The return-air compartment is in acceptable condition.
Informational

6.8 · Heat Pump Disconnect

The electrical disconnect at the condensing coil is functional.
Informational

6.9 · Refrigerant Lines

The refrigerant lines are in acceptable condition.
Informational

6.10 · Thermostats

The thermostat is functional.
Functional

6.11 · Registers

The registers are reasonably clean and functional.
Informational

6.12 · Distribution System

The distribution system has been extended to service the garage, which is contrary to Utah Building and Safety standards. You may wish to get a second opinion from an HVAC specialist, but in any event, we highly recommend that the extension is completely removed for reasons of safety.
Needing Service

6.13 · Metal Ducting

The ducts have no visible deficiencies. They are a rigid metal type that are insulated with fiberglass.
Functional

7 · Heat

Forced-Air Furnaces

7.1 · Age & Location

Central heat is provided by a 1 year-old forced-air furnaces that are located in the washroom.
Informational

7.2 · Common Observations

The furnace needs to be serviced. This service should be scheduled within the inspection period, because a specialist might reveal additional defects or recommend upgrades that could affect your evaluation of the systems.
Needing Service

7.3 · Furnace

The furnace is functional.
Informational

7.4 · Gas Valve & Connector

The gas valve and connector are in acceptable condition.
Informational

7.5 · Thermostats

The thermostat is functional.
Informational

7.6 · Registers

The registers are reasonably clean and functional.
Informational

7.7 · Metal Ducting

The metal ducts are a rigid metal type insulated with fiberglass. However, significant portions of the ducts are concealed and cannot be viewed.
Informational

8 · Interior Comments

Smoke Detectors

8.1 · Smoke Detector Observations

The residence is not equipped with smoke detectors, which are mandated and should be installed in appropriate locations, and in accordance with state and local ordinances.
Needing Service

Carbon Monoxide Detectors

8.2 · Carbon Monoxide Detector Observations

The residence is not equipped with carbon monoxide alarms, which are required by state law. At least one carbon monoxide alarm is required, and should be installed in a location consistent with the manufacturers installation instructions and local ordinances.
Needing Service

9 · Living

Main Entry

9.1 · No Recommended Service

We evaluated this area and found it to be in acceptable condition.
Informational

9.2 · Doors

The doors are functional.
Functional

9.3 · Flooring

The floor is worn or cosmetically damaged, which you should view for yourself.
Informational

9.4 · Walls & Ceiling

The walls have typical cosmetic damage.
Informational

9.5 · Closets

The hardware of the closet door needs to be serviced for the door to operate properly.
Informational

9.6 · Single-Glazed Windows

The windows will need service to work well, such as sanding, shaving, trimming, or servicing the hardware. Recommend replacing.
Informational

9.7 · Lights

There is an open electrical junction box, which should be sealed.
Needing Service

9.8 · Outlets

The outlets that were tested are functional.
Functional

10 · Kitchen

Kitchen

10.1 · No Recommended Service

We have evaluated the kitchen, and found it to be in acceptable condition.
Informational

10.2 · Doors

The doors are functional.
Informational

10.3 · Flooring

The floor is worn or cosmetically damaged, which you should view for yourself.
Informational

10.4 · Walls & Ceiling

The walls and ceiling are in acceptable condition.
Functional

10.5 · Kitchen Closet or Pantry

The components of the closet or pantry are in acceptable condition.
Informational

10.6 · Single-Glazed Windows

The windows are functional.
Informational

10.7 · Cabinets

The cabinets are functional, and do not have any significant damage.
Functional

10.8 · Faucet

The sink faucet is functional.
Functional

10.9 · Trap and Drain

The sink drains too slowly, and should be serviced.
Needing Service

10.10 · Garbage Disposal

The garbage disposal is functional.
Functional

10.11 · Electric Range

The electric range is functional, but was neither calibrated nor tested for its performance.
Functional

10.12 · Electric Cooktop

The electrical cook top is functional.
Functional

10.13 · Dishwasher

The dishwasher is not functional and should be repaired or replaced.
Needing Service

10.14 · Exhaust Fan or Downdraft

The exhaust fan is functional and a type that vents internally.
Informational

10.15 · Lights

The light is functional.
Informational

10.16 · Outlets

The outlets that were tested are functional and include ground-fault protection.
Functional

10.17 · Portable Microwave Oven

We do not evaluate portable microwave ovens as a part of our service.
Informational

11 · Attic

Attic

11.1 · Primary Attic Access Location

The attic can be accessed through a hatch in the garage.
Informational

11.2 · Method of Evaluation

We evaluated the attic by direct access.
Informational

11.3 · Framing

The roof framing consists of a factory-built truss system, comprised of components called chords, webs, and struts that are connected by wood or metal gussets nailed or glued in place. Each component of the truss is designed for a specific purpose, and cannot be removed or modified without compromising the integrity of the entire truss. The lowest component, which is called the chord and to which the ceiling is attached, can move by thermal expansion and contraction and cause creaking sounds, which are more pronounced in the mornings and evenings along with temperature changes. Such movement has no structural significance, but can result in small cracks or divots in the drywall or plaster.
Informational

11.4 · Ventilation

Ventilation is provided by a combination of eave, dormer, turbine, or gable vents, and should be adequate. We do not evaluate, nor do we operate or check the function of solar or electric powered ventilator fans.
Informational

11.5 · Plumbing Vents

The drainpipe vents that are fully visible are in acceptable condition.
Informational

11.6 · Blown-in Fiberglass Insulation

The attic floor is well insulated with an average of twelve or more inches of blown-in fiberglass insulation. This gives the attic an approximate insulation resistance rating, or R-Value, of R-30 or greater. Loose-fill or blown-in insulation will vary in thermal performance due to factors such as aging, mean temperature, settlement, convection, moisture absorption and installation variation. Convection in glass loose-fill insulation installed in open attics can reduce its thermal performance in extreme winter temperatures during the heating season.
Informational

12 · Hallway

Hallway

12.1 · No Recommended Service

We have evaluated the hallway, and found it to be in acceptable condition.
Informational

13 · Bedrooms

Master Bedroom

13.1 · No Recommended Service

We have evaluated this bedroom and found it to be in acceptable condition.
Informational

13.2 · Doors

The door is functional.
Functional

13.3 · Closets

The closet and its components are functional.
Functional

First Guest Bedroom

13.4 · No Recommended Service

We have evaluated this bedroom and found it to be in acceptable condition.
Informational

Second Guest Bedroom

13.5 · No Recommended Service

We have evaluated this bedroom and found it to be in acceptable condition.
Informational

14 · Laundry

Laundry Room

14.1 · No Recommended Service

We have evaluated the laundry room, and found it to be in acceptable condition.
Informational

14.2 · Flooring

The floor has no significant defects.
Informational

14.3 · 240 Volt Receptacle

The 240 volt circuit and receptacle are functional.
Functional

14.4 · Outlets

The outlet has an open ground, and should be serviced by a qualified electrician.
Needing Service

15 · Garage

Double-Car Garage

15.1 · No Recommended Service

We have evaluated the garage, and found it to be in acceptable condition.
Informational

15.2 · Parking Space

The parking space has been restricted by the addition of partition walls. Therefore, it would be prudent for you to see that the parking space is adequate to accommodate your vehicles.
Further Investigation Advised

15.3 · Entry Door Into the House

The house entry door is not identified as being fire-rated and must be to maintain the necessary firewall separation between a garage and living quarters, and will need to be replaced.
Needing Service

15.4 · Garage Door & Hardware

The garage door and its hardware are functional.
Functional

15.5 · Automatic Opener

The garage door opener is functional.
Functional

15.6 · Outlets

The outlets should be upgraded to include ground fault protection, which is mandated by current standards and is an important safety feature.
Recommended Safety Upgrade

16 · Pool and Spa

Pool & Spa

16.1 · General Comments

It is important to note that in general, city, county and state ordinances require that swimming pools be maintained in a clean and sanitary condition, and in good repair.
Informational

16.2 · General Comments

The pool and spa systems cannot be adequately evaluated without having an appropriate amount of water to operate the equipment. You should have the pool filled, and all equipment should be thoroughly tested and verified to be operating properly by a qualified contractor, during your inspection contingency period. This is important because the cost of replacing the equipment may significantly affect your evaluation of the property.
Needing Service